I-BS-2082F yoPhando lwe-Fluorescent Biological Microscope

Emva kweminyaka yophando kunye nophuhliso kwicandelo letekhnoloji ye-Optical, i-BS-2082F yebhayoloji yemakroskopu iyilelwe ukubonisa amava oqwalaselo akhuselekileyo, akhululekileyo nafanelekileyo kubasebenzisi. Ngesakhiwo esenziwe ngokugqibeleleyo, umfanekiso we-optical high-definition kunye nenkqubo elula yokusebenza, i-BS-2082F iqonda uhlalutyo lobuchwephesha, kwaye ihlangabezana nazo zonke iimfuno zophando kwisayensi, ezonyango kunye nezinye iinkalo.


Iinkcukacha zeMveliso

Khuphela

Ulawulo lwemeko

Iithegi zeMveliso

I-BS-2082F yoPhando lweBiological Mikroskopu

BS-2082F

Intshayelelo

Emva kweminyaka yophando kunye nophuhliso kwicandelo letekhnoloji ye-Optical, i-BS-2082 yebhayoloji ye-microscope yenzelwe ukubonisa amava oqwalaselo akhuselekileyo, akhululekileyo nafanelekileyo kubasebenzisi. Ngesakhiwo esenziwe ngokugqibeleleyo, umfanekiso we-optical high-definition kunye nenkqubo elula yokusebenza, i-BS-2082 iqonda uhlalutyo lobuchwephesha, kwaye ihlangabezana nazo zonke iimfuno zophando kwisayensi, ezonyango kunye nezinye iinkalo.

Uphawu

I-BS-2082 yoPhando lwe-Biological Microscope yamehlo

eyepiece yeso eliphezulu ibala elibanzi.

Indawo yokujonga i-eyepiece iye yaphuculwa ukusuka kwi-22mm yendabuko ukuya kwi-25mm kunye ne-26.5mm, ibonelele ngakumbi indawo yokujonga kunye nokuphucula ukusebenza kakuhle. Ngoluhlu olubanzi lohlengahlengiso lwe-diopter kunye nerubha esongelayo yokugada iliso.

Intloko yokujonga ngomlinganiselo wokuqhekeka okuninzi.

Intloko yokujonga yenzelwe iinketho ezininzi zokwahlula umlinganiselo.
(1) Intloko ye-Trinocular enomfanekiso ojijekileyo, umlinganiselo wokwahlulwa kweBinocular: Trinocular=100:0 okanye 20:80 okanye 0:100 ngokuqhelekileyo. Ngaphandle kokugxininisa ukukhanya kwe-100% kwi-tube ye-eyepiece okanye i-tube yekhamera, kukho enye inketho kunye ne-20% yokukhanya kwi-tube eyepiece kunye ne-80% kwi-tube yekhamera, ukwenzela ukuba ukubonwa kwe-eyepiece kunye nokukhutshwa komfanekiso kunokufumaneka ngexesha elifanayo.
(2) Intloko ye-Trinocular enomfanekiso omisiweyo, umlinganiselo wokwahlula i-Binocular:Trinocular=100:0 okanye 0:100 ayinyanzelekanga. Ulwalathiso oluhambayo lweesampulu luyafana nokubonwayo.

I-BS-2082 yoPhando lweBiological Mikroskopu iNtloko

Isigaba esikhulu esingenasiphelo sezandla zombini.

Iqonga elikhulu elinohlengahlengiso kuzo naziphi na izandla Ukuze kulungiswe ingozi efihliweyo yomzila kaloliwe wesikhokelo se-horizon, iqonga liyilwe ngendlela ephindwe kabini kwindlela yokuqhuba. Olu tshintsho lukhusela isiteji ekugqithiseni ngokugqithiseleyo ekupheleni kweereyile zombini, kuphucula ukuthembeka kunye nokusebenza kweqonga.

Umqheba weqonga unokusetwa kwicala ngalinye ngokusekelwe kukhetho lwabasebenzisi. Uhlengahlengiso lwe-X, Y lwe-biaxial luyilwe kwindawo ephantsi ukuze lusebenze kakuhle.

Izilayi ezibini zinokubanjwa eqongeni ngokusebenzisa iikliphu eziphindwe kabini zohlobo lokumanzisa, kulula ukuthelekisa uphononongo. Uluhlu oluhambayo: 80mm X55mm; ukuchaneka: 0.1mm. Ukucutshungulwa ngobuchwephesha obukhethekileyo, umgangatho weqonga uchasene ne-corrosive and anti-friction. Iqonga elinoyilo lwenguqu ye-arc linciphisa uxinzelelo loxinzelelo kunye nomonakalo kwimpembelelo.

I-BS-2082 yoPhando lweBiological Microscope Stage

Isakhelo semodyuli, ukuphucula ukuhambelana kwenkqubo.

Ngoyilo lwemodyuli, ingalo eyohluliweyo kunye nomzimba ophambili, iphucula ukuhambelana kwenkqubo yebhayoloji kunye nesakhelo se-fluorescence.

I-coaxial ebukhali kakhulu kunye nenkqubo yohlengahlengiso elungileyo.

Uhlengahlengiso lwe-coaxial luthatha inqanaba eliphindwe kabini lokuqhuba, kunye nokuqina koxinzelelo olulungelelaniswayo kunye nokumisa umda ongaphezulu, uluhlu olurhabaxa luyi-25mm kunye nokuchaneka okuhle yi-1μm. Akukona nje ukugxila ngokuchanekileyo kodwa kunye nomlinganiselo ochanekileyo okhoyo.

img

Isicelo

Le microscope sisixhobo esifanelekileyo kwi-biological, histological, pathological, bacteriology, ugonyo kunye nentsimi yekhemesti kwaye inokusetyenziswa ngokubanzi kumaziko ezonyango kunye nococeko, iilebhu, amaziko, iilebhu zemfundo, iikholeji kunye neeyunivesithi.

Inkcazo

Into

Inkcazo

BS-2082

BS-2082F

BS-2082

MH10

Inkqubo yokubona Umbala ongapheliyo walungisa inkqubo yamehlo

Intloko yokuJonga Intloko ye-Seidentopf trinocular (Umfanekiso oguqulweyo), i-30 ° inclined, interpupillary distance: 50mm-76mm; Umlinganiselo wokwahlula i-Eyepiece:Trinocular=100:0 okanye 20:80 okanye 0:100

Intloko ye-Seidentopf trinocular (Umfanekiso omisiweyo), i-30 ° ethambekele, umgama we-interpupillary: 50mm-76mm; Umlinganiselo wokwahlula i-Eyepiece:Trinocular=100:0 okanye 0:100

Isixhobo samehlo I-eyepoint ebanzi yeplani ye-eyepiece ye-PL10X / 25mm, i-diopter ehlengahlengiswayo

Isicwangciso samehlo esibanzi sendawo ebanzi ye-PL10X/25mm, ene-reticle, i-diopter ehlengahlengiswayo

I-eyepoint ebanzi yeplani ye-eyepiece ye-PL10X / 26.5mm, i-diopter adjustable

Isicwangciso samehlo esiphakamileyo esibanzi se-PL10X/26.5mm, sine-reticle, i-diopter ehlengahlengiswayo

Injongo Cwangcisa injongo ye-semi-apochromatic fluorescent 4X/0.13(infinity), WD=18.5mm

Cwangcisa injongo ye-semi-apochromatic fluorescent 10X/0.30(infinity), WD=10.6mm

Cwangcisa injongo ye-semi-apochromatic fluorescent 20X/0.50(infinity), WD=2.33mm

Cwangcisa injongo ye-semi-apochromatic fluorescent 40X/0.75(infinity), WD=0.6mm

Cwangcisa injongo ye-semi-apochromatic fluorescent 100X/1.30(infinity), WD=0.21mm

Nosepiece (ene DIC slot) Ngasemva Quintuple Nosepiece

Ngasemva Sextuple Nosepiece

Ngasemva Septuple impumlo

Isakhelo Isakhelo sebhayoloji (esidluliselweyo), indawo ephantsi ye-coaxial erhabaxa kunye nohlengahlengiso oluhle, umgama wohlengahlengiso orhabaxa: 25mm; ukuchaneka kakuhle: 0.001mm. Ngokumisa uhlengahlengiso olurhabaxa kunye nohlengahlengiso lokuqina.
I-100-240V_AC50 / 60Hz i-voltage ebanzi ye-voltage ye-100-240/60Hz, ukuqina okuguquguqukayo ngokusetwa kwedijithali kunye nokusetha kwakhona; izihluzo ezakhelwe ngaphakathi ezithunyelwayo LBD/ND6/ND25)

Isakhelo se-Fluorescence (esisasazwayo), indawo ephantsi ye-coaxial coaxial kunye nokulungelelaniswa okuhle, umgama wohlengahlengiso onqabileyo: 25mm; ukuchaneka kakuhle: 0.001mm. Ngokumisa uhlengahlengiso olurhabaxa kunye nohlengahlengiso lokuqina.
I-100-240V_AC50 / 60Hz i-voltage ebanzi ye-voltage ye-100-240/60Hz, ukuqina okuguquguqukayo ngokusetwa kwedijithali kunye nokusetha kwakhona; izihluzo ezakhelwe ngaphakathi ezithunyelwayo LBD/ND6/ND25)

Iqonga Imigangatho ephindwe kabini inqanaba lomatshini, ubukhulu: 187mm X168mm; uluhlu oluhambayo: 80mm X55mm; ukuchaneka: 0.1mm; Indlela ezimbini zokuqhuba emgceni, uxinzelelo olunokulungiswa

Icondenser Uhlobo lwe-Swing-out i-achromatic condenser (NA0.9)

Isikhanyisi se-fluorescence esibonakalisiweyo I-Sextuple ibonise isikhanyisi se-fluorescence kunye ne-iris field diaphragm kunye ne-aperture diaphragm, ephakathi kulungelelaniswa; nge-slot yokucoca kunye ne-polarizing slot; ngezihluzi ze-fluorescence (UV/B/G yokhetho).

I-100W indlu yesibane se-mercury, iziko le-filament kunye nokugxilwa kwe-adjustable; ngesipili esibonakalisiweyo, iziko lesipili kunye nogxininiso olunokulungiswa. (Indlu yesibane ye-xenon engama-75W yokhetho)

Umlawuli wamandla wedijithali, umbane obanzi 100-240VAC

Isibane semercury esithathwe ngaphandle kwe-OSRAM 100W.( OSRAM 75W xenon isibane sokhetho)

Ukhanyiso oluThunyelweyo I-12V / 100W indlu yesibane se-halogen yokukhanya okugqithisiweyo, ukusetwa kwangaphambili kwendawo, ukuqina okuguquguqukayo

Ezinye izincedisi I-adaptha yekhamera: 0.5X/0.65X/1X igxile kwi-C-mount

Ikhamera yeCCD epholileyo, SONY 2/3′′, 1.4MP, ICX285AQ Umbala weCCD

Injongo yokubeka iziko lokuqwalaselwa kwefluorescence

Isilayidi solungelelwaniso 0.01mm

I-Attachment yokuJonga kaninzi yabantu aba-5

DIC isiqhoboshelo

Qaphela: ● Isinxibo esiMgangatho, ○ Ngokuzikhethela

Imizekelo yeMifanekiso

2082 (2)
2082 (1)

Isatifikethi

mhg

Ulungiselelo

umfanekiso (3)

  • Ngaphambili:
  • Okulandelayo:

  • I-BS-2082 Series yoPhando lwe-Biological Microscope

    umfanekiso (1) umfanekiso (2)